LED Screen Power-Up and Shutdown Procedure

Step-by-step guide to safely powering up and shutting down your LED display. Includes the critical warm-up sequence to protect power supplies and extend screen lifespan.

Overview

This procedure covers the correct sequence for shutting down and powering up your LED display. For general day-to-day use, the correct approach is to leave the screen powered on and simply set the controller to a blank input or black output — not to switch power off.

Frequent full power cycling places unnecessary thermal and electrical stress on internal components and will shorten their working life. This procedure should only be used following a planned shutdown, power outage, or maintenance event, and should always be followed in full to protect the display's power supplies.

Why a Slow Warm-Up Matters

Bringing the display up to full brightness gradually — rather than switching straight to 100% — reduces inrush current and thermal stress on the power supplies as they start up, letting them reach a stable operating temperature before carrying full load.

Following the warm-up sequence set out below at every start-up will help protect the power supplies and extend their working life.

Shutdown Procedure

Before You Power Back Up: Always allow the screen to cool fully before re-powering. The power-up sequence below is what protects your power supplies — please read it in full before switching the display back on.

Confirm display brightness is fully down to 0% (blank input or black output) — check the front panel (and any management software such as NovaLCT, if used) reads 0% before continuing. Set the video source or test pattern to black. Switch off in sequence: isolator switch(es) first , followed by the circuit breaker(s) . If any insulation resistance testing or similar work is to be carried out on the supply cabling, the screen must first be physically isolated by disconnecting its input power cables from the supply. Skipping this step may result in abnormal operation or damage to internal screen components.

Power-Up and Warm-Up Procedure

Ensure the screen has been allowed to cool before re-powering (following a shutdown or fault condition). Confirm controller brightness is set to 0% before applying power — the display should be outputting black at this stage. Power the display back on in sequence: circuit breaker(s) first , followed by the isolator switch(es) , allowing approximately 10 seconds between each. If input power cables were disconnected for isolation, reconnect these before switching the isolator(s) on. Bring the video source online and confirm it is live and outputting a proper signal, turning off any test pattern. The source should now be fully live — but brightness must stay at 0% (screen still black) until you're ready to begin the warm-up below. With the source confirmed live and brightness still at 0%, begin the brightness warm-up sequence below, increasing gradually only once you're ready. Do not skip stages or shorten the hold times — this is the step that protects the power supplies.

Brightness Warm-Up Sequence (~100 Minutes Total)

Gradually increase brightness using the following schedule:

Stage Brightness Level Hold Duration 1 1% 10 minutes 2 10% 10 minutes 3 20% 10 minutes 4 30% 10 minutes 5 40% 10 minutes 6 50% 10 minutes 7 60% 10 minutes 8 70% 10 minutes 9 80% 10 minutes 10 90% 10 minutes Final 100% Hold and resume automatic brightness control

Do not skip stages or shorten the hold times — this gradual warm-up is what protects the power supplies from inrush current and thermal stress.

Note on Software-Controlled Brightness

If brightness has previously been set to 0% within display management software (e.g. NovaLCT), that software value should be returned to 100% only after Stage 1 has been set on the controller's front panel — not before.

Once the full warm-up sequence is complete, brightness can be handed back to the display's normal automatic brightness strategy.

Support Contact

For technical support or servicing enquiries, contact Aurora Displays:

Phone: 1300 841 542 Email: sales@aurorasignage.com.au Web: aurorasignage.com.au